Logo
Logo


ISSN: 0300-9041
ISSNe: 2594-2034


Indizada en: SciELO, Índice Médico Latinoamericano, LILACS, Medline
Editada por la Federación Mexicana de Colegios de Obstetricia, y Ginecologia AC
Fundada por la Asociación Mexicana de Ginecología y Obstetricia en 1945
 

INFORMACIÓN EXCLUSIVA PARA LOS PROFESIONALES DE LA SALUD


Periodicidad: continua
Abreviatura: Ginecol Obstet Mex
ISSN: 0300-9041
ISSNe: 2594-2034
Indizada en: Scimago, Índice Médico Latinoamericano, Lilacs, Medline, Science Citation Index, Ulrich, Ebsco.

Desempeño diagnóstico del modelo FullPIERS como predictor de complicaciones perinatales en pacientes con preeclampsia

Diagnostic performance of FullPIERS model as predictor of perinatal complications in patients with preeclampsia.

Ginecol Obstet Mex. 2020 enero;88(1):1-7.

https://doi.org/10.24245/gom.v88i1.325

Ingrid América Cazarez-Ávalos,1 Demnsi García-Benavente,1 Cinthia Nallely Toledo-Lorenzo,1 Jaime Guadalupe Valle-Leal,2 Diego Misael López-Valenzuela1

1 Departamento de  Ginecología y Obstetricia.
2 Departamento de Educación e Investigación en Salud.
Hospital General Regional 1, Instituto Mexicano del Seguro Social, Ciudad Obregón, Sonora, México.


Corrrespondencia:

Jaime Guadalupe Valle Leal
Valle_jaime1@hotmail.com

Debe citarse como:

Cazarez-Ávalos IA, García-Benavente D, Toledo-Lorenzo CN, Valle-Leal JG, López-Valenzuela DM. Desempeño diagnóstico del modelo FullPIERS como predictor de complicaciones perinatales en pacientes con preeclampsia. Ginecol Obstet Mex. 2020 enero;88(1):1-7. https://doi.org/10.24245/gom.v88i1.3253

Resumen

OBJETIVO: Determinar el desempeño diagnóstico del modelo FullPIERS como predictor de complicaciones perinatales en pacientes con preeclampsia atendidas en un hospital público del Noroeste de México.

MATERIALES Y MÉTODO: Estudio retrospectivo, para evaluación de una prueba diagnóstica, efectuado en pacientes con diagnóstico de preeclampsia atendidas en un hospital público de segundo nivel entre octubre de 2018 y febrero 2019. Criterios de inclusión: expedientes con datos suficientes para introducirlos en la calculadora FullPIERS (saturación de oxígeno, recuento de plaquetas, creatinina, aspartato, transaminasa y existencia o no de disnea). Criterios de exclusión: pacientes con diagnóstico previo de padecimientos hepáticos agudos, pulmonares o renales. Se comparó el porcentaje de riesgo al ingreso de cada paciente versus la cantidad de pacientes con y sin complicaciones. Se calcularon: sensibilidad, especificidad y valores predictivos del modelo.

RESULTADOS: Se estudiaron 100 expedientes de pacientes con preeclampsia: 11 con resultados positivos según la calculadora Full PIERS (más de 5% de riesgo), en 7 de 11 fue verdadero positivo. Para el modelo Full PIERS se obtuvieron: sensibilidad de 58.3% y especificidad de 95.5%, valor predictivo positivo de 59%, y valor predictivo negativo de 95% para la predicción de complicaciones de la preeclampsia, con área bajo la curva de 0.799.

CONCLUSIÓN: La calculadora FullPIERS es una herramienta útil para predecir complicaciones a corto plazo y poder indicar el tratamiento adecuado a cada paciente.

PALABRAS CLAVES: Embarazo; preeclampsia; complicaciones; creatinina; enfermedades renales; FullPIERS.

Abstract

OBJECTIVE: To determine the diagnostic performance of the FullPIERS model as a predictor of perinatal complications in patients with preeclampsia from a public hospital in Northwest Mexico.

MATERIALS AND METHODS: Retrospective study, for the evaluation of a proper diagnosis, performed in patients with diagnosis of preeclampsia attended at a second-level public hospital between October 2018 and February 2019. Inclusion criteria: sufficient data to introduce them into the FullPIERS calculator (saturation of oxygen, platelet retreat, creatinine, aspartate, transaminases and the existence of dysnea). Exclusion criteria: patients with previous diagnosis of acute, pulmonary or renal liver diseases. It is compared to the percentage of the ingrowth risk of each patient versus the number of patients with complications. Calculated: sensitivity, specificity and predictive values ​​of the model.

RESULTS: If 100 patients were studied with preeclampsia: 11 with positive results according to the Full PIERS calculator (over 5% risk), and 7 out of 11 were true. For the Full PIERS model, it was obtained: 58.3% sensitivity and 95.5% specificity, 59% positive predictive value, and 95% negative predictive value for the prediction of complications of preeclampsia, with a curve area of ​​0.799.

CONCLUSION: The FullPIERS calculator is a useful tool for predicting complications to cut and can indicate the appropriate treatment for each patient.

KEYWORDS: Pregnancy; Pre-Eclampsia; Complications; Creatinine; Oxygen; Kidney diseases. FullPIERS.

    1. Khan KS, et al. WHO analysis of causes of maternal death: a systemic review. Lancet 2006; 367:1066-74. http://www.africanwomenshealthfoundation.com/attachments/WHO%20KSK%20maternal%20mortality.pdf
    2. Say L, et al. Global causes of maternal death: a WHO systemic analysis. Lancet 2014; 2: 323-33. https://doi.org/10.1016/S2214-109X(14)70227-X
    3. Prevención, diagnóstico y tratamiento de la preeclampsia en segundo y tercer nivel de atención. Evidencias y Recomendaciones. Guía de Práctica Clínica. México. IMSS; 2017. http://www.imss.gob.mx/sites/all/statics/guiasclinicas/020GER.pdf
    4. Akkermans J, et al. Predicting complications in pre-eclampsia: external validation of the fullPIERS model using the PETRA trial dataset. Eur J Obstet Gynecol Reprod Biol 2014; 179: 58-62. http://dx.doi.org/10.1016/j.ejogrb.2014.05.021
    5. Von Dadelszen P, et al. Prediction of adverse maternal outcomes in pre-eclampsia: development and validation of the fullPIERS model. Lancet 2011; 377 (9761): 219-27. https://doi.org/10.1016/S0140-6736(10)61351-7
    6. Payne B, et al. Performance of the fullPIERS model in predicting adverse maternal outcomes in pre-eclampsia using patient data from the PIERS (Pre-eclampsia Integrated Estimate of RiSk) cohort, collected on admission. BJOG 2013; 120 (1):113-18. http://dx.doi.org/10.1111/j.1471-0528.2012.03496.x
    7. Srivastava S, et al. PIERS calculator- predicting adverse maternal outcome in preeclampsia. Int J Reprod Contracept Obstet Gynecol 2017; 6 (4):1200-205. http://dx.doi.org/10.18203/2320-1770.ijrcog20170889
    8. Kuklina EV, et al. Hypertensive disorders and severe obstetric morbidity in the United States. Obstet Gynecol 2009; 113 (6): 1299-306. https://doi.org/10.1097/AOG.0b013e3181a45b25
    9. Muñoz E, et al. Aplicación de la escala de factores de riesgo para complicaciones de preeclampsia. Rev Chil Obstet Ginecol 2017; 82(4):438-446. http://dx.doi.org/10.4067/s0717-75262017000400438
    10. Ukah UV, et al. External validation of the fullPIERS model for predicting adverse maternal outcomes in pregnancy hypertension in low- and middle-income countries. Hypertension 2017; 69(4):705-11. https://doi.org/10.1161/HYPERTENSIONAHA.116.08706
    11. Almeida ST, et al. Validation of fullPIERS model for prediction of adverse outcomes among women with severe pre-eclampsia. Int J Gynaecol Obstet 2017; 138 (2):142-47. https://doi.org/10.1002/ijgo.12197

Comentarios