Logo
Logo


ISSN: 0300-9041
ISSNe: 2594-2034


Indizada en: SciELO, Índice Médico Latinoamericano, LILACS, Medline
Editada por la Federación Mexicana de Colegios de Obstetricia, y Ginecologia AC
Fundada por la Asociación Mexicana de Ginecología y Obstetricia en 1945
 

INFORMACIÓN EXCLUSIVA PARA LOS PROFESIONALES DE LA SALUD


Periodicidad: continua
Abreviatura: Ginecol Obstet Mex
ISSN: 0300-9041
ISSNe: 2594-2034
Indizada en: Scimago, Índice Médico Latinoamericano, Lilacs, Medline, Science Citation Index, Ulrich, Ebsco.

Himen como punto de corte para el prolapso genital sintomático

Hymen as a cut-off point for symptomatic genital prolapse.

Ginecol Obstet Mex. 2019 septiembre;87(9):583-589.

https://doi.org/10.24245/gom.v87i9.3163

Esther Silvia Rodríguez-Colorado,1 Carlos Ramírez-Isarraraz,2 Verónica Granados-Martínez,2 Viridiana Gorbea-Chávez,3 José Jonatán Olvera-Delgado4

1 Coordinadora de la clínica de Urología ginecológica.
2 Adscrito a la Clínica de Urología ginecológica.
3 Directora de Educación en Ciencias de la Salud.
4 Residente de segundo año de Urología ginecológica.
Instituto Nacional de Perinatología Isidro Espinosa de los Reyes, Ciudad de México.


Corrrespondencia:

José Jonatán Olvera Delgado
jonas_o7@hotmail.com

Debe citarse como:

Rodríguez-Colorado ES, Ramírez-Isarraraz C, Granados-Martínez V, Gorbea-Chávez V, Olvera-Delgado JJ. Himen como punto de corte para el prolapso genital sintomático. Ginecol Obstet Mex. 2019 septiembre;87(9):583-589. https://doi.org/10.24245/gom.v87i9.3163

Resumen

OBJETIVO: Evaluar el valor discriminatorio de los puntos de corte anatómicos para prolapso sintomático, en mujeres con prolapso de órganos pélvicos.

MATERIALES Y MÉTODOS: Estudio de cohorte retrospectivo, efectuado en la Clínica de Urología ginecológica del Instituto Nacional de Perinatología Isidro Espinosa de los Reyes, entre enero de 2013 y diciembre 2017. Criterios de inclusión: pacientes intervenidas por prolapso de órganos pélvicos, con cuantificación del prolapso de órganos pélvicos simplificado (S-POP) e interrogatorio de los síntomas del piso pélvico según la Sociedad Internacional de Continencia (ICS). Se calculó la sensibilidad, especificidad, valor predictivo positivo y área bajo la curva para puntos de corte del compartimento anterior (Ba), posterior (Bp) y apical (C).

RESULTADOS: Se incluyeron 174 pacientes. El síntoma de sensación de cuerpo extraño en la vagina aumentó simultáneamente conforme al grado de prolapso. Las áreas bajo la curva (AUC) para el punto Ba fueron: 0.73 (IC95% 0.65-0.81), Bp 0.63 (IC95%: 0.53-0.72) y C 0.78 (IC95%: 0.71-0.85). Al utilizar el himen como punto de corte se observó que el punto Ba tuvo sensibilidad de 0.76 y especificidad de 0.54, Bp con sensibilidad de 0.54 y especificidad 0.86 y para C el punto de corte -5 cm con respecto al himen tuvo  sensibilidad de 0.66 y especificidad de 0.75.

CONCLUSIÓN: Existe un adecuado valor discriminatorio entre el himen como punto de corte para el prolapso de órganos pélvicos sintomático y sensación de cuerpo extraño en la vagina, según los criterios del sistema de cuantificación simplificado (S-POP).

PALABRAS CLAVE: Prolapso de órganos pélvicos; piso pélvico; sensación de cuerpo extraño; himen; vagina.

Abstract

OBJECTIVE: To evaluate the discriminatory value of anatomical cut-off points for symptomatic prolapse in women with pelvic organ prolapse.

MATERIALS AND METHODS: Retrospective cohort study, conducted at the Gynecological Urology Clinic of the National Institute of Perinatology, between January 2013 and December 2017. Inclusion criteria: patients operated for pelvic organ prolapse, with simplified quantification system of pelvic organ prolapse (S-POP) and interrogation of pelvic floor symptoms according to the International Continence Society (ICS). Sensitivity, specificity, positive predictive value and area under the curve for cut-off points of the anterior (Ba), posterior (Bp) and apical (C) compartments were calculated.

RESULTS: 174 patients were included. The symptom of a foreign body sensation in the vagina increased simultaneously with the degree of prolapse. The areas under the curve (AUC) for point Ba was 0.73 (95% CI 0.65-0.81), Bp 0.63 (95% CI 0.53-0.72) and C 0.78 (95% CI 0.71-0.85). When using the hymen as a cut-off point it was observed that Ba showed a sensitivity of 0.76 and specificity of 0.54, Bp with sensitivity of 0.54 and specificity 0.86 and for C the cut-off point of -5 cm with respect to the hymen had sensitivity of 0.66 and specificity of 0.75.

CONCLUSION: There is adequate discriminatory value between the hymen as a cut-off point for symptomatic pelvic organ prolapse and foreign body sensation in the vagina, according to the criteria of the simplified quantification system (S-POP).

KEYWORDS: Pelvic organ prolapse; Pelvic floor symptoms; Foreign body sensation; Hymen; Vagina.

    1. Haylen BT, et al. An International Urogynecological Association (IUGA)/International Continence Society (ICS) Joint Report on the Terminology for Female Pelvic Organ Prolapse (POP): International Urogynecological Association (IUGA). Neurourol Urodyn 2016;35(2):137-68. DOI: 10.1007/s00192-015-2932-1
    2. Geynisman-Tan J, et al. Surgical updates in the treatment of pelvic organ prolapse. Rambam Maimonides Med J 2017;8(2). DOI: 10.5041/RMMJ.10294
    3. Cetinkaya SE, et al. Correlation of pelvic organ prolapse staging with lower urinary tract symptoms, sexual dysfunction, and quality of life. Int Urogynecol J 2013;24(10):1645-50. DOI: 10.1007/s00192-013-2072-4
    4. Dietz HP, et al. What is clinically relevant prolapse? An attempt at defining cutoffs for the clinical assessment of pelvic organ descent. Int Urogynecol J 2014;25(4):451-5. DOI: 10.1007/s00192-013-2307-4
    5. Manonai J, et al. The inter-system association between the simplified pelvic organ prolapse quantification system (S-POP) and the standard pelvic organ prolapse quantification system (POPQ) in describing pelvic organ prolapse. Int Urogynecol J 2011;22(3):347-52. DOI: 10.1007/s00192-010-1286-y
    6. Swift S, et al. Validation of a simplified technique for using the POPQ pelvic organ prolapse classification system. Int Urogynecol J 2006;17(6):615-20. DOI: 10.1007/s00192-006-0076-z
    7. Eusebi P. Diagnostic accuracy measures. Cerebrovasc Dis 2013;36(4):267-72. DOI: 10.1159/000353863
    8. Swift S, et al. Pelvic Organ Support Study (POSST): The distribution, clinical definition, and epidemiologic condition of pelvic organ support defects. Am J Obstet Gynecol. marzo de 2005;192(3):795-806. DOI: 10.1016/j.ajog.2004.10.602
    9. Manonai J, et al. Relationship between pelvic floor symptoms and POP-Q measurements: Relationship Between Pelvic Floor Symptoms and POP-Q. Neurourol Urodyn 2016;35(6):724-7. DOI: 10.1002/nau.22786
    10. Gutman RE, et al. Is there a pelvic organ prolapse threshold that predicts pelvic floor symptoms? Am J Obstet Gynecol 2008;199(6):683.e1-683.e7. DOI: 10.1016/j.ajog.2008.07.028
    11. Barber MD, et al. Can we screen for pelvic organ prolapse without a physical examination in epidemiologic studies? Am J Obstet Gynecol 2006;195(4):942-8. DOI: 10.1016/j.ajog.2006.02.050
    12. Miedel A, et al. Symptoms and pelvic support defects in specific compartments: Obstet Gynecol 2008;112(4):851-8. DOI: 10.1097/AOG.0b013e318187c550
    13. Willis BH. Spectrum bias--why clinicians need to be cautious when applying diagnostic test studies. Fam Pract 2008;25(5):390-6. DOI: 10.1093/fampra/cmn051
    14. Leeflang MMG, et al. Diagnostic test accuracy may vary with prevalence: implications for evidence-based diagnosis. J Clin Epidemiol 2009;62(1):5-12. DOI: 10.1016/j.jclinepi.2008.04.007
    15. Mulherin SA, et al. Spectrum Bias or Spectrum Effect? Subgroup variation in diagnostic test evaluation. Ann Intern Med 2002;137(7):598. DOI: 10.7326/0003-4819-137-7-200210010-00011

Comentarios